PTSV platinum vibration-resistant reference resistance thermometers

DESIGNED FOR
PTSV platinum vibration-proof reference resistance thermometers (hereafter thermometers) are designed for verification of temperature measuring instruments in accordance with State verification schedule for temperature measuring instruments (GOST 8.558-2009) and for use as a temperature measuring instrument of improved accuracy in various industries and scientific research.
Thermometers are portable devices, composed of primary thermal transducer – a sensitive element of a platinum thermometer (CHEPT) and a protective housing.
The principle of operation of thermometers is to use the temperature dependence of platinum electrical resistance.

SPHERES OF APPLICATION
engineering, scientific reseach, different areas requiring high precision temperature measurements.

Thermometer modification Index Total length, mm Length of immersed part, mm Diameter of head, mm Diameter of immersed part, mm
PTSV -1 MGFK.405111.001 595 ± 5 550 ± 5 22 ± 0,5 6 ± 0,2
MGFK.405111.001-01 575 ± 5 530 ± 5 22 ± 0,5 6 ± 0,2
PTSV -2 MGFK.405111.002 74 ± 1 50 ± 1 6 ± 0,2 4± 0,2
PTSV -2К MGFK.405111.006 От 50 до 130 (± 1) 50 ± 1 6 ± 0,2 4± 0,2
PTSV -3 MGFK.405111.003 626 ± 5 550 ± 5 22 ± 0,5 6 ± 0,2
MGFK.405111.003-01 426 ± 2 350 ± 2 22 ± 0,5 6 ± 0,2
PTSV -4 MGFK.405111.004 629 ± 5 550 ± 5 22 ± 0,5 6 ± 0,2
PTSV -5 MGFK.405111.005 629 ± 5 550 ± 5 22 ± 0,5 6 ± 0,2
MGFK.405111.005-01 426 ± 2 350 ± 2 22 ± 0,5 6 ± 0,2

 

PTSV platinum vibration-resistant reference resistance thermometers

 

Modification and thermometer version Category Range of temperature measurement, ̊С WGa,

not less than

WHg,

not more than

W100,

not less than *)

PTSV -1-2 2 Minus 50 …450 1.11795 0.844235 1.3924
PTSV -1-3 3 Minus 50 …450 1.11795 0.844235 1.3924
PTSV -2-1 1 Minus 200 …100 1.11795 0.844235 1.3924
PTV -2К-1 1 Minus 60 …60 1.11795 0.844235 1.3924
PTSV -2-2 2 Minus 200 …200 1.11795 0.844235 1.3924
PTSV -2К-2 2 Minus 200 …200 1.11795;

1.11750

0.844235;

0.844990

1.3924;

1.3908

PTSV -2К-2 2 Minus 60 …60 1.3908;
1.385
PTSV -2-3 3 Minus 200 …200 1.11750 0.844990 1.3908
PTSV -2К-3 3 Minus 200 …200 1.11750 0.844990 1.3908
PTSV -2К-3 3 Minus 200 …200 1.385
PTSV -3-3 3 Minus 50 …500 1.11795 0.844235 1.3924
PTSV -4-2 2 Minus 50 … 232 1.11795 0.844235 1.3924
PTSV -4-3 3 Minus 50 … 232 1.11795 0.844235 1.3924
PTSV -5-3 3 Minus 50 … 250 1.11750 0.844990 1.3908

1 WGa – relative resistivity at gallium melting point

2 WHg – relative resistivity at mercury triple point temperature

3 W100 – relative resistivity at temperature of 100 °С